SpectraMax® iD5 Service & Repair

At Analytical Technologies Group, we specialize in both the maintenance and repair of a very narrow range of products, including the SpectraMax® iD5. We believe that by limiting our services to only a small repertoire of items, we are able to provide our clients with an unmatched quality of service. Spare parts are almost always in stock, which means even less down-time for you. Having doubts? Ask the 2000 customers ATG has kept satisfied. You rely on your equipment. Your equipment should rely on ATG.

Tips for keeping your SpectraMax® iD5 in good order: 

  • Always turn the power off and disconnect the power cord from the main power source before you use liquids to clean the instrument.

  • Keep the injectors and accessories clean by periodically cleaning the outside surfaces, the inside and outside of the bottle holder, the snorkel clamps, and the snorkel end of the injector tubing with a lint-free cloth that has been lightly dampened with water. You can remove the bottle holder for cleaning.

  • If decontamination is required, use a lint-free cloth that has been lightly dampened with a decontaminating solution, such as 70% ethanol or 3% sodium hypochlorite. 

  • To clean the waste plate, strip wells, bottles, and adapters, use a lightly dampened, lint-free cloth. After you clean these accessories, let them air dry on absorbent paper or cloth. Invert the waste plate, strip wells, and bottles so that they drain as they dry. These accessories can be replaced if cleaning is no longer practical.

  • To clean the injector tips, remove the bottles from the bottle holder. Dab the surface of the injectors with a lightly dampened, lint-free cloth. Do not insert anything into the injector tips as this can damage their internal non-stick coating.

  • To clean the inside of the injector tubing, use the Wash operation

  • Wipe off visible dust from exterior surfaces with a lint-free cloth to avoid dust build up on the instrument.

  • Wipe up all spills immediately.

  • Follow applicable decontamination procedures as instructed by your laboratory safety officer.

Having technical problems with your SpectraMax® iD5?

 

Fast Response

We provide very prompt responses to customers within one business day.

Fast Turnaround

Our field service engineers are expediently dispatched across North America & Europe to fulfill your service request.

Expert Staff

ATG’s highly trained, highly skilled staff ensure your instruments remain in optimal condition.

Parts In Stock

To minimize instrument downtime, we stock virtually all parts for the systems in which we specialize.

 

SpectraMax® iD5 Troubleshooting Tips:

  • Respond as required to all error messages the software displays.

  • If the instrument does not seem to get power after you switch it on, check to see whether the power cord is securely plugged into a functioning power outlet and to the power port on the rear of the instrument.

  • If the power failed while the instrument was on, verify that the power cord is not loose or disconnected and that power to the power outlet is functioning properly.

  • If these checks fail to remedy the loss of power, replace the fuses. You can obtain replacement fuses from Molecular Devices.

If your problem persists, your SpectraMax® iD5 may require professional help. Contact ATG for prompt, qualified service.

ATG: YOUR PARTNER IN BIOPROCESS SERVICE, SUPPORT and MAINTENANCE