Service for Agilent® Headspace Samplers


You rely on your equipment. Your equipment should rely on ATG.

At Analytical Technologies Group, we specialize in the maintenance and repair of Agilent® Headspace Samplers. Because we focus on these systems and keep a deep inventory of critical spare parts, we can deliver fast, dependable service that keeps your volatile analyses running at full capacity.

Headspace samplers like the 7697 and G1888 need consistent, expert care to keep vial pressurization stable, sample transfer precise and carryover low. A leaking 6-port valve, a contaminated sample loop or a faulty vial gripper can halt your sample throughput and put your results at risk. For years, experienced scientists have trusted ATG to keep their Agilent headspace samplers performing exactly as designed. You should too.

  • Agilent® 7697 Headspace Sampler

  • Agilent® G1888 Headspace Sampler

Tips for keeping your Agilent® Headspace Sampler in good order:

Before Each Sequence:

  • Use vials that meet the sampler’s size specifications.

  • Avoid reusing vials; reused vials can crack when heated.

  • Never reuse crimp caps or septa.

  • Fill vials about half full so the sample probe never touches the sample.

  • Check that caps are centered, finger-tight and free of folds or wrinkles.

Regularly:

  • Watch the maintenance counters and service parts as they come due.

  • Reset each counter after completing its maintenance.

  • Run a leak and restriction test.

As Needed:

  • Clean the vial tray, racks and carousel, and vacuum up any broken glass.

  • Clean up spills promptly and replace vial tray seals if needed.

  • Clean the oven if a vial breaks inside it.

Having technical problems with your Agilent® Headspace Sampler?

 

Fast Response

We provide very prompt responses to customers within one business day.

Fast Turnaround

Our field service engineers are expediently dispatched across North America & Europe to fulfill your service request.

Expert Staff

ATG’s highly trained, highly skilled staff ensure your instruments remain in optimal condition.

Parts In Stock

To minimize instrument downtime, we stock virtually all parts for the systems in which we specialize.

 

Agilent® Headspace Sampler Troubleshooting Tips:

Poor repeatability:

  • Crimp every vial consistently and check each one before loading.

  • Use the same vial type and fill volume throughout the sequence.

  • Make sure the sample loop and transfer line temperatures are high enough.

Carryover or ghost peaks:

  • Raise the loop and transfer line temperatures to prevent condensation.

  • Increase the purge flow and time between injections.

  • Clean the 6-port valve and rotor.

Shifting retention times:

  • Check for leaks at the transfer line and GC inlet fittings.

  • Replace the GC inlet septum.

  • Confirm carrier gas pressure and flow settings.

ATG: YOUR PARTNER IN BIOPROCESS SERVICE, SUPPORT and MAINTENANCE