Service for Agilent® Automatic Liquid Samplers


You rely on your equipment. Your equipment should rely on ATG.

At Analytical Technologies Group, we specialize in the maintenance and repair of Agilent® Automatic Liquid Samplers. Because we focus on these systems and keep a deep inventory of critical spare parts, we can deliver fast, dependable service that keeps your GC injections running at full capacity.

Workhorse autosamplers like the 7683 and 7693 need consistent, expert care to keep injections precise, vial handling reliable and carryover low. A misaligned turret, a worn plunger mechanism or a faulty tray gripper can halt your sample throughput and put your results at risk. For years, experienced scientists have trusted ATG to keep their Agilent autosamplers performing exactly as designed. You should too.

  • Agilent® 7683 Automatic Liquid Sampler

  • Agilent® 7693 Automatic Liquid Sampler

Tips for keeping your Agilent® Automatic Liquid Sampler in good order:

Before Each Sequence:

  • Install a new or clean syringe and rinse it with solvent.

  • Use only cone-tip syringes; sharp tips tear the inlet septum.

  • Roll the syringe on a flat surface to make sure the needle is straight.

  • Check that the plunger slides smoothly without sticking.

Regularly:

  • Replace the inlet septum about every 200 injections.

  • Tighten the septum nut only enough to seal; overtightening shortens septum life.

  • Check that the needle is centered over the septum nut.

  • Replace the inlet liner, or clean and deactivate it.

After Changing the Turret:

  • Run the turret alignment so the needle samples at the correct depth.

Having technical problems with your Agilent® Automatic Liquid Sampler?

 

Fast Response

We provide very prompt responses to customers within one business day.

Fast Turnaround

Our field service engineers are expediently dispatched across North America & Europe to fulfill your service request.

Expert Staff

ATG’s highly trained, highly skilled staff ensure your instruments remain in optimal condition.

Parts In Stock

To minimize instrument downtime, we stock virtually all parts for the systems in which we specialize.

 

Agilent® Automatic Liquid Sampler Troubleshooting Tips:

Bent syringe needles:

  • Make sure the syringe is seated correctly in the carriage.

  • Confirm you’re using the correct syringe type and length.

  • Make sure the injection mode matches the inlet.

Dropped or mishandled vials:

  • Check crimp caps for folds or wrinkles near the vial neck.

  • Use vials that meet the sampler’s size specifications.

  • Make sure labels are the right size and aren’t catching on the gripper.

Poor reproducibility (retention times or peak areas):

  • Replace a leaking inlet septum.

  • Check needle alignment if septa wear out before 200 injections.

  • Clean or replace a dirty or sticking syringe.

Ghost peaks or contamination:

  • Run solvent blanks to confirm where the peaks come from.

  • Use flat, centered vial septa to prevent coring.

  • Use vial septa rated for your solvent.

ATG: YOUR PARTNER IN BIOPROCESS SERVICE, SUPPORT and MAINTENANCE